Skip to main content
Regional validity

Scope

solid wood construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 80,0 1700
B 0,3 300
C 120,0 Perlite fill (loose expanded perlite) 100 kg/m³, moist 100 1,000
D 35,0 20
E 0,3 separation nonwoven
F 1,8 sealing sheet 0,170 1200 E
G - variable building material
H - variable insulation material
I 4,0 0,230 1100 E
J 0,2
K 150,0 cross laminated timber 5-ply 0,130 50 500 1,600 D

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
fdmogo01-00 G
H
0,5
360,0

752,0 60 0,10 adequate 55 (-4,-9) 239,01 274,2
fdmogo01-01 G
H

260,0

652,0 60 0,10 adequate 55 (-4,-9) 133,02 241,0

Last update 05.08.2024/hfa.plb