Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A Plastic roofing membrane or E
A sheet metal roofing 7800 A1
B 24,0 spruce wood closed cladding without spacing of cladding boards 0,120 50 450 1,600 D
C 80,0 spruce wood counter battens (ventilation) 0,120 50 450 1,600 D
D sarking membrane sd ≤ 0,3m 1000 E
E 22,0 softboard [045; 250] - rigid underlay 0,045 5 250 2,100 E
F construction timber (80/*; e=800) 0,120 50 450 1,600 D
G - variable insulation material
H 16,0 particleboard 0,130 50-100 700 1,700 D
I vapour barrier sd≥ 1m 1000
J 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
K 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
K 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
fdrhbi02b-00 F
G
200,0
200,0
construction timber
mineral wool [040; ≥16; <1000°C]
391,0 60 0,19 adequate 47 (-2,-6) 41,63 52,9
fdrhbi02b-01 F
G
220,0
220,0
construction timber
mineral wool [040; ≥16; <1000°C]
419,0 60 0,18 adequate 48 (-3,-7) 42,86 54,2
fdrhbi02b-02 F
G
240,0
240,0
construction timber
mineral wool [040; ≥16; <1000°C]
139,0 60 0,17 adequate 48 (-2,-6) 44,09 55,5
fdrhbi02b-03 F
G
200,0
200,0
construction timber
mineral wool [035; 50; <1000°C]
391,0 60 0,18 adequate 48 (-2,-6) 64,23 59,1
fdrhbi02b-04 F
G
200,0
200,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
391,0 60 0,19 adequate 47 (-2,-6) 47,46 56,0
fdrhbi02b-05 F
G
200,0
200,0
construction timber
cellulose fibre [040; E]
391,0 60 0,19 adequate 48 (-3,-7) 34,74 60,0
fdrhbi02b-06 F
G
200,0
200,0
construction timber
sheep wool [0,041; R=26]
391,0 60 0,21 adequate 47 (-3,-7) 35,56 52,9

Last update 02.08.2023/nu.ge