Cross-section of standard configuration
Standard configuration
Note
The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.
Register of building materials used for this application, cross-section
(from top to bottom)
|
Thickness [mm] |
Building material |
Thermal performance |
Reaction to fireklasse EN |
| λ |
μ min – max |
ρ |
c |
| A |
|
Plastic roofing membrane
or
|
|
|
|
|
E
|
| A |
|
sheet metal roofing
|
|
|
7800
|
|
A1
|
| B |
24,0
|
spruce wood
closed cladding without spacing of cladding boards
|
0,120
|
50
|
450
|
1,600
|
D
|
| C |
80,0
|
spruce wood
counter battens (ventilation)
|
0,120
|
50
|
450
|
1,600
|
D
|
| D |
15,0
|
fibreboard (MDF)
|
0,140
|
11
|
600
|
1,700
|
D
|
| D |
|
sarking membrane sd ≤ 0,3m
|
|
|
1000
|
|
E
|
| E |
|
construction timber
(80/*; e=800)
|
0,120
|
50
|
450
|
1,600
|
D
|
| F |
|
- variable insulation material
|
|
|
|
|
|
| G |
|
vapour barrier sd≥ 1m
|
|
|
1000
|
|
|
| H |
50,0
|
spruce wood
cross battens (50/80;a=400)
|
0,120
|
50
|
450
|
1,600
|
D
|
| I |
|
- variable insulation material
or without insulation in type 01
|
|
|
|
|
|
| J |
25,0
|
gypsum fibre board
(2x12,5 mm) or
|
0,320
|
21
|
1000
|
1,100
|
A2
|
| J |
25,0
|
gypsum plaster board type DF
(2x12,5 mm)
|
0,250
|
10
|
800
|
1,050
|
A2
|
Variations of building components
|
Thickness of layer |
Note |
Fire performance |
Thermal performance |
Acoustic performance |
Eco Sustainability |
Mass |
|
Thickness [mm] |
Building material |
Σ |
REI |
U [W/(m²K)] |
Diffusion |
Rw (C,Ctr) [dB] |
ΔOI3 |
m [kg/m²] |
|
fdrhbi08b-00
|
E
F
I
|
200,0
200,0
50,0
|
construction timber
mineral wool [040; ≥16; <1000°C]
mineral wool [040; ≥16; <1000°C]
|
389,0
|
|
60
|
0,18
|
adequate
|
50
(-3,-8)
|
38,80
|
47,6
|
|
fdrhbi08b-01
|
E
F
I
|
200,0
200,0
|
construction timber
mineral wool [040; ≥16; <1000°C]
- variable insulation material
|
389,0
|
I=without insulation
|
60
|
0,21
|
adequate
|
48
(-3,-8)
|
35,97
|
47,0
|
|
fdrhbi08b-02
|
E
F
I
|
220,0
220,0
50,0
|
construction timber
mineral wool [040; ≥16; <1000°C]
mineral wool [040; ≥16; <1000°C]
|
409,0
|
|
60
|
0,17
|
adequate
|
50
(-2,-7)
|
40,03
|
48,9
|
|
fdrhbi08b-03
|
E
F
I
|
240,0
240,0
50,0
|
construction timber
mineral wool [040; ≥16; <1000°C]
mineral wool [040; ≥16; <1000°C]
|
429,0
|
|
60
|
0,16
|
adequate
|
51
(-2,-7)
|
41,26
|
50,2
|
|
fdrhbi08b-04
|
E
F
I
|
200,0
200,0
50,0
|
construction timber
mineral wool [035; 50; <1000°C]
mineral wool [035; 50; <1000°C]
|
389,0
|
|
60
|
0,16
|
adequate
|
51
(-3,-8)
|
66,42
|
55,1
|
|
fdrhbi08b-05
|
E
F
I
|
200,0
200,0
50,0
|
construction timber
mineral wool [038; ≥33; ≥1000°C]
mineral wool [038; ≥33; ≥1000°C]
|
389,0
|
|
60
|
0,18
|
adequate
|
50
(-2,-7)
|
45,93
|
51,4
|
|
fdrhbi08b-06
|
E
F
I
|
200,0
200,0
50,0
|
construction timber
cellulose fibre [040; E]
cellulose fibre [040; E]
|
389,0
|
|
60
|
0,18
|
adequate
|
50
(-3,-8)
|
30,38
|
56,2
|
|
fdrhbi08b-07
|
E
F
I
|
200,0
200,0
50,0
|
construction timber
sheep wool [0,041; R=26]
sheep wool [0,041; R=26]
|
389,0
|
|
60
|
0,20
|
adequate
|
50
(-4,-9)
|
31,39
|
47,6
|
Last update 02.08.2023/nu.ge