Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A sheet metal roofing or 7800 A1
A Plastic roofing membrane E
B 24,0 spruce wood closed cladding without spacing of cladding boards 0,120 50 450 1,600 D
C 80,0 spruce wood counter battens (ventilation) 0,120 50 450 1,600 D
D 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
D sarking membrane sd ≤ 0,3m 1000 E
E construction timber (80/..; e=800) 0,120 50 450 1,600 D
F - variable insulation material
G 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
H spruce wood cross battens (50/80;a=400) 0,120 50 450 1,600 D
I - variable insulation material
J 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
J 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
fdrhbi10a-00 E
F
H
I
200,0
200,0
50,0
50,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
396,5 30 0,18 adequate 47 (-3,-7) 39,28 47,3
fdrhbi10a-01 E
F
H
I
200,0
200,0
50,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
396,5 I=without insulation 30 0,21 adequate 45 (-3,-7) 36,45 46,7
fdrhbi10a-02 E
F
H
I
220,0
220,0
50,0
50,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
416,5 30 0,17 adequate 47 (-2,-6) 40,51 48,6
fdrhbi10a-03 E
F
H
I
240,0
240,0
50,0
50,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
436,5 30 0,16 adequate 48 (-2,-6) 41,75 49,8
fdrhbi10a-04 E
F
H
I
200,0
200,0
50,0
50,0
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
396,5 30 0,16 adequate 48 (-3,-7) 66,91 54,8
fdrhbi10a-05 E
F
H
I
200,0
200,0
50,0
50,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
396,5 30 0,18 adequate 47 (-2,-6) 46,41 51,0
fdrhbi10a-06 E
F
H
I
200,0
200,0
50,0
50,0
construction timber
cellulose fibre [040; E]
spruce wood
cellulose fibre [040; E]
396,5 30 0,18 adequate 46 (-2,-6) 30,86 55,9
fdrhbi10a-07 E
F
H
I
200,0
200,0
50,0
50,0
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=26]
396,5 30 0,20 adequate 46 (-3,-7) 31,87 47,3

Last update 02.08.2023/hfa.eco2soft