Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 60
maximum span = 4 m; maximum load Ed,fi = 7,92 kN/m²  
Classified by IBS  
Thermal performance U 0,11 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 57 dB
Ln,w (Cl)
Rating by IFT  
Mass per unit area m 115,4 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A sheet metal roofing trapezoidal sheet metal roofing 7800 A1
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C 80,0 spruce wood counter battens 0,120 50 450 1,600 D
D 22,0 softboard [047; 200] 0,047 3-7 200 2,100 E
E 240,0 softboard [040; 110] insulation placed on top of the rafters 0,040 3-7 110 2,100 E
F sealing sheet
G 100,0 cross laminated timber BBS 125 5 layer 0,130 50 470 1,600 D
H 70,0 spruce wood battens (60/60; e=625) mounted on resilient clips 0,120 50 450 1,600 D
I 50,0 mineral wool [040; 18] 0,040 1 18 1,030 A1
J 15,0 gypsum plaster boards Rigips RF or 0,250 10 900 1,050 A2
J 15,0 gypsum fibre board Rigidur H 0,350 19 1200 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 114,2
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -51,503 0,492 0,204 8,59e-6 0,031 214,762 1405,131 1619,893 1530,184 186,077 1716,260

Source: Saint-Gobain Rigips Austria GesmbH