Building physical assessment

Fire performance REI 30
Classified by HFA  
Thermal performance U 0,21 W/(m2K)
Diffusion adequate
Acoustic performance Rw (C;Ctr) 43 dB (-2; -7)
Ln,w (Cl)
Mass per unit area m 88,5 kg/m2
 
solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A gravel
B
C sealing sheet sd≥ 100m
D 200,0 mineral wool [040; 130; ≥1000°C] (2*100) 0,040 1 130 1,030 A1
E sealing sheet e.g. bitumen
F 125,0 cross laminated timber ≥ 125,0; at least 5-layers, top layer at least 27,5 mm) 0,130 50 500 1,600 D

Ecological rating (per m2 construction area)

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 61,2 kg
Biogenic carbon 88,1 kgCO2 Äqv.
Energy use of Primary Energy 1,195,0 MJ
Share of renewable PE 24,3 %

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -41,290 0,296 0,044 4,15E-6 0,028 289,721 1.040,824 1.328,045 883,615 140,852 1.023,769
C1 - C4 101,796 0,004 0,008 1,57E-7 0,001 0,947 -1.036,250 -1.035,304 19,526 0,000 19,526
A1 - C4 62,726 0,300 0,052 4,31E-6 0,029 290,676 4,574 292,750 904,294 140,852 1.044,448