flat roof solid wood construction, not ventilated, without dry lining, without lining
Fire performance | REI | 30 |
---|---|---|
Classified by HFA
|
||
Thermal performance | U | 0,21 W/(m2K) |
Diffusion | adequate | |
Acoustic performance | Rw (C;Ctr) | 43 dB (-2; -7) |
Ln,w (Cl) | ||
Mass per unit area | m | 88,5 kg/m2 |
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | no additional structure gravel | ||||||
B | no additional structure | ||||||
C | sealing sheet sd≥ 100m | ||||||
D | 200,0 | mineral wool [040; 130; ≥1000°C] (2*100) | 0,040 | 1 | 130 | 1,030 | A1 |
E | sealing sheet e.g. bitumen | ||||||
F | 125,0 | cross laminated timber ≥ 125,0; at least 5-layers, top layer at least 27,5 mm) | 0,130 | 50 | 500 | 1,600 | D |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 75,585 | -91,470 | -15,885 | 56,829 | 855,000 | 911,829 | 1093,756 | 198,054 | 1291,810 | 0,457 | 0,143 | 6.4681688E-6 | 0,175 |
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP [kgCO2Äqv.] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
A1 - A3 | -41,290 | 0,296 | 0,044 | 4.15E-6 | 0,028 | 289,721 | 1040,824 | 1328,045 | 883,615 | 140,852 | 1023,769 |
C1 - C4 | 101,796 | 0,004 | 0,008 | 1.57E-7 | 0,001 | 0,947 | -1036,250 | -1035,304 | 19,526 | 0,000 | 19,526 |
A1 - C4 | 62,726 | 0,300 | 0,052 | 4.31E-6 | 0,029 | 290,676 | 4,574 | 292,750 | 904,294 | 140,852 | 1044,448 |