flat roof solid wood construction, not ventilated, without dry lining, without lining
Fire performance | REI | 30 |
---|---|---|
Classified by HFA
|
||
Thermal performance | U | 0,21 W/(m2K) |
Diffusion | adequate | |
Acoustic performance | Rw (C;Ctr) | 43 dB (-2; -7) |
Ln,w (Cl) | ||
Mass per unit area | m | 94,5 kg/m2 |
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | no additional structure gravel | ||||||
B | no additional structure | ||||||
C | sealing sheet sd≥ 100m | ||||||
D | 200,0 | wood-fibre insulation board [0,045; R=160] (2*100) | 0,045 | 5-7 | 160 | 2,100 | E |
E | sealing sheet e.g. bitumen | ||||||
F | 125,0 | cross laminated timber ≥ 125,0; at least 5-layers, top layer at least 27,5 mm) | 0,130 | 50 | 500 | 1,600 | D |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 65,446 | -149,790 | -84,344 | 104,562 | 1445,414 | 1549,976 | 1057,448 | 253,825 | 1311,272 | 0,296 | 0,125 | 7.2072267E-6 | 0,071 |
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP [kgCO2Äqv.] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
A1 - A3 | -104,046 | 0,147 | 0,030 | 3.29E-6 | 0,031 | 487,535 | 1541,674 | 2026,708 | 863,747 | 138,424 | 1001,470 |
C1 - C4 | 147,119 | 0,002 | 0,000 | 1.51E-7 | 0,000 | 1,853 | -1541,674 | -1539,821 | 26,883 | -35,374 | -8,491 |
A1 - C4 | 43,073 | 0,148 | 0,030 | 3.45E-6 | 0,031 | 489,387 | 0,000 | 486,888 | 890,630 | 103,050 | 992,980 |
Last update 02.08.2023/hfa.eco2soft