Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
flat roof solid wood construction, not ventilated, with dry lining, suspended
Fire performance | REI | 60 |
---|---|---|
maximum span = 5 m; maximum load Ed,fi = 0,6 kN/m²
Classified by HFA
|
||
Thermal performance | U | 0,10 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 52 dB |
Ln,w (Cl) | ||
Rating by HFA
|
||
Mass per unit area | m | 127,1 kg/m2 |
Calculation based on gypsum plaster board type DF GKF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | Plastic roofing membrane | E | |||||
B | 300,0 | wood-fibre insulation board [0,045; R=160] ; pressure-resistant | 0,045 | 5-7 | 160 | 2,100 | E |
C | sealing sheet | ||||||
D | 125,0 | cross laminated timber ≥ 125,0; at least 5-layers, top layer at least 27,5 mm | 0,130 | 50 | 500 | 1,600 | D |
E | 80,0 | spruce wood ; battens on resilient clips (50/80; e=625) | 0,120 | 50 | 450 | 1,600 | D |
F | 80,0 | mineral wool [040; 18] | 0,040 | 1 | 18 | 1,030 | A1 |
G | 12,5 | gypsum plaster board type DF / gypsum fibre board | 0,250 | 10 | 800 | 1,050 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 87,372 | -184,286 | -96,914 | 150,634 | 1793,031 | 1943,665 | 1403,966 | 281,710 | 1685,676 | 0,387 | 0,166 | 9.0865552E-6 | 0,084 |
Last update 02.08.2023/hfa.eco2soft