Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 30
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²  
Classified by HFA  
Thermal performance U 0,16 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 50 dB (-2; -7)
Ln,w (Cl)
Rating by TGM  
Mass per unit area m 35,8 kg/m2
Calculation based on gypsum plaster board type DF GF
 

data sheet flat roof
fdrhbi01a-02 (pdf, 250 KB)

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A sheet metal roofing or plastic roofing membrane 7800 A1
A Plastic roofing membrane E
B 24,0 spruce wood closed cladding without spacing of cladding boards 0,120 50 450 1,600 D
C 80,0 spruce wood counter battens (ventilation) 0,120 50 450 1,600 D
D sarking membrane sd ≤ 0,3m 1000 E
E 22,0 softboard [045; 250] - rigid underlay 0,045 5 250 2,100 E
F 220,0 construction timber (80/*; e=800) 0,120 50 450 1,600 D
G 220,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
H vapour barrier sd≥ 2m 1000
I 50,0 spruce wood cross battens (50/80;a=400) 0,120 50 450 1,600 D
J 50,0 mineral wool [040; ≥16; <1000°C] or without insulation in type 01 0,040 1 16 1,030 A1
K 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
K 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 35,3 kg
Share of renewable materials of total weight 65,31 %
Global warming potential (GWP-T) -23,731 kgCO2Äqv.
Energy use of Primary Energy 659,8 MJ
Share of renewable Primary Energy 15,9 %
∑ΔOI3 38,3
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 34,167 -57,898 -23,731 105,186 597,920 703,106 554,594 19,383 573,977 0,173 0,082 2.8225835E-6 0,032

Last update 02.08.2023/hfa.eco2soft