Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
flat roof timber frame construction, ventilated, with dry lining, not suspended
Fire performance | REI | 30 |
---|---|---|
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²
Classified by HFA
|
||
Thermal performance | U | 0,17 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 50 dB (-3; -8) |
Ln,w (Cl) | ||
Rating by TGM
|
||
Mass per unit area | m | 43,1 kg/m2 |
Calculation based on gypsum plaster board type DF GF
|
data sheet flat roof
fdrhbi01a-06 (pdf, 250 KB)
The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | sheet metal roofing or plastic roofing membrane | 7800 | A1 | ||||
A | Plastic roofing membrane | E | |||||
B | 24,0 | spruce wood closed cladding without spacing of cladding boards | 0,120 | 50 | 450 | 1,600 | D |
C | 80,0 | spruce wood counter battens (ventilation) | 0,120 | 50 | 450 | 1,600 | D |
D | sarking membrane sd ≤ 0,3m | 1000 | E | ||||
E | 22,0 | softboard [045; 250] - rigid underlay | 0,045 | 5 | 250 | 2,100 | E |
F | 200,0 | construction timber (80/*; e=800) | 0,120 | 50 | 450 | 1,600 | D |
G | 200,0 | cellulose fibre [040; E] | 0,040 | 1-2 | 55 | 2,000 | E |
H | vapour barrier sd≥ 2m | 1000 | |||||
I | 50,0 | spruce wood cross battens (50/80;a=400) | 0,120 | 50 | 450 | 1,600 | D |
J | 50,0 | cellulose fibre [040; E] or without insulation in type 01 | 0,040 | 1-2 | 55 | 2,000 | E |
K | 12,5 | gypsum fibre board or | 0,320 | 21 | 1000 | 1,100 | A2 |
K | 12,5 | gypsum plaster board type DF | 0,250 | 10 | 800 | 1,050 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 30,138 | -68,224 | -38,086 | 106,396 | 704,892 | 811,288 | 437,957 | 19,383 | 457,340 | 0,148 | 0,068 | 2.2063087E-6 | 0,028 |
Last update 02.08.2023/hfa.eco2soft