Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 60
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²  
Classified by HFA  
Thermal performance U 0,17 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 50 dB (-3; -8)
Ln,w (Cl)
Rating by TGM  
Mass per unit area m 44,5 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet flat roof
fdrhbi05b-02 (pdf, 250 KB)

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A trapezoidal sheet metal roofing A1
B 80,0 spruce wood battens (80/50) 0,120 50 450 1,600 D
C 50,0 spruce wood counter battens (ventilation) 0,120 50 450 1,600 D
D sarking membrane sd ≤ 0,3m 1000 E
E 22,0 softboard [045; 250] - rigid underlay 0,045 5 250 2,100 E
F 240,0 construction timber (80/..; e=800) 0,120 50 450 1,600 D
G 240,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
I 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
I vapour barrier sd≥ 2m 1000
J 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
J 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 25,4 kg
Share of renewable materials of total weight 39,34 %
Global warming potential (GWP-T) 20,411 kgCO2Äqv.
Energy use of Primary Energy 1033,2 MJ
Share of renewable Primary Energy 9,1 %
∑ΔOI3 74,4
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 61,443 -41,032 20,411 94,532 417,762 512,294 938,623 19,383 958,006 0,293 0,143 4.2804181E-6 0,050

Last update 02.08.2023/hfa.eco2soft