Building physical assessment

Fire performance REI 30
maximum span = 5 m; maximum load Ed,fi = 2,6 kN/m²  
Classified by HFA  
Fire performance Germany
Classification: F30  
Load Ed,fi according to the German certification document
Proof: DIN 4102-4:2016-05, Tabelle 10.19, Zeile 1  
Thermal performance U 0,15 W/(m2K)
Diffusion adequate
Attention: Due to the application of a moisture-adaptive vapour barrier an object-related proof according to protection against moisture (diffusion) is mandatory. A hygrothermic simulation is necessary (e.g. WUFI)  
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 51 dB (-4; -9)
Ln,w (Cl)
Assessed by Müller-BBM  
Mass per unit area m 156,7 kg/m2
 

Datenblatt flat roof
fdroba01a-00 (pdf, 250 KB)

Note

ATTENTION: Regarding protection against moisture an object-related proof in terms of paramter like e.g. climate, shading class etc. is required. Therfore a hygrothermic simulation is necessary (e.g.WUFI), a simple Glaser calculation ist not allowed.

timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A Plastic roofing membrane /metal sheeting on structured separation layer E
B 25,0 OSB 0,130 200 600 1,700 D
C 240,0 construction timber (80/..; e=800) 0,120 50 450 1,600 D
D 240,0 mineral wool [040; 30; ≥1000°C] 0,040 1 30 1,030 A1
E moisture-adaptive vapour retarder E
F 40,0 acoustic hanger
G 40,0 mineral wool [040; 30; ≥1000°C] 0,040 1 30 1,030 A1
H 15,0 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 43,0
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -9,510 0,191 0,057 2,93e-6 0,038 65,837 449,585 515,422 478,730 92,312 571,042

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 32,9 kg
Biogenic carbon 48,9 kgCO2 Äqv.
Energy use of Primary Energy 761,4 MJ
Share of renewable PE 24,2 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -21,259 0,152 0,022 1,18e-6 0,028 182,764 570,582 752,588 558,562 61,117 619,740
C1 - C4 54,980 0,003 0,003 7,08e-8 0,001 0,952 -563,858 -562,908 10,624 -13,238 -2,614
A1 - C4 36,890 0,157 0,026 1,26e-6 0,029 184,204 6,982 190,427 577,188 47,943 625,192

Last update 10.06.2020/hfa.plb