floor towards attic (uninhabitable) solid wood construction, not suspended, dry, wooden surface
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 300,0 | mineral wool [040; 130; ≥1000°C] | 0,040 | 1 | 130 | 1,030 | A1 |
B | foil (air tight) | ||||||
C | 125,0 | cross laminated timber ≥ 125mm; 5-ply at least, surface layer at least 27,5 | 0,130 | 50 | 500 | 1,600 | D |
D | 80,0 | spruce wood battens (50/80; e=400) | 0,120 | 50 | 450 | 1,600 | D |
E | 80,0 | mineral wool [040; 20] | 0,040 | 1 | 20 | 1,030 | A2 |
F | - variable building material |
Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] |
Last update 02.08.2023/nu.ge