Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 18,0 OSB 0,130 200 600 1,700 D
B 240,0 spruce wood floor joists (80/*); e=625 0,120 50 450 1,600 D
C - variable insulation material
D vapour barrier sd≥ 15m 1000
E 60,0 acoustic direct hanger decoupled with CD-profile (a=400)
F 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
F 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
ddrtxa01b-00 C 240,0 mineral wool [038; ≥30] 343,0 60 0,18 adequate 63 (-4,-11) 41,11 54,0

Last update 02.08.2023/hfa.eco2soft