Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 19,0 particleboard 0,130 50-100 700 1,700 D
B 220,0 construction timber (80/..; e=625) 0,120 50 450 1,600 D
C - variable insulation material
D vapour barrier sd≥ 8m 1000
E 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
F 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
F 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
ddrtxn07a-00 C 220,0 mineral wool [040; 11; <1000°C] 275,5 30 0,19 adequate 42 (-2,-6) 17,60 40,8

Last update 02.08.2023/hfa.eco2soft