Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 60
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²  
Classified by HFA  
Thermal performance U 0,18 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 43 dB (-1; -5)
Ln,w (Cl)
Rating by TGM  
Mass per unit area m 79,7 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 50,0 Magnesite-bound lightweight wood wool board 0,120 2-5 700 1,400
B 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
C 220,0 construction timber (80/..; e=*) 0,120 50 450 1,600 D
D 220,0 mineral wool [038; ≥33; ≥1000°C] 0,038 1 33 1,030 A1
E vapour barrier sd≥ 2m 1000
F 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
G 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
G 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 35,9 kg
Share of renewable materials of total weight 51,69 %
Global warming potential (GWP-T) -13,242 kgCO2Äqv.
Energy use of Primary Energy 477,6 MJ
Share of renewable Primary Energy 16,5 %
∑ΔOI3 30,6
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 32,208 -45,450 -13,242 78,694 447,344 526,037 398,916 4,459 403,375 0,145 0,046 1.9519746E-6 0,053

Last update 02.08.2023/nu.ge