Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
floor towards attic (uninhabitable) timber frame construction, not suspended, dry, Gipsplatte
Fire performance | REI | 60 |
---|---|---|
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²
Classified by HFA
|
||
Thermal performance | U | 0,20 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 43 dB (-3; -7) |
Ln,w (Cl) | ||
Rating by TGM
|
||
Mass per unit area | m | 76,4 kg/m2 |
Calculation based on gypsum plaster board type DF GKF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 50,0 | Magnesite-bound lightweight wood wool board | 0,120 | 2-5 | 700 | 1,400 | |
B | 24,0 | spruce wood cladding with spacing of cladding boards(24/100); a=400 | 0,120 | 50 | 450 | 1,600 | D |
C | 220,0 | construction timber (80/..; e=*) | 0,120 | 50 | 450 | 1,600 | D |
D | 220,0 | sheep wool [0,041; R=16] | 0,041 | 1 | 16 | 1,720 | E |
E | vapour barrier sd≥ 2m | 1000 | |||||
F | 24,0 | spruce wood cladding with spacing of cladding boards(24/100); a=400 | 0,120 | 50 | 450 | 1,600 | D |
G | 25,0 | gypsum plaster board type DF (2x12,5 mm) or | 0,250 | 10 | 800 | 1,050 | A2 |
G | 25,0 | gypsum fibre board (2x12,5 mm) | 0,320 | 21 | 1000 | 1,100 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 26,471 | -51,003 | -24,531 | 74,716 | 518,003 | 592,718 | 301,188 | 5,150 | 306,338 | 0,067 | 0,028 | 1.8665203E-6 | 0,016 |