Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 60
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²  
Classified by HFA  
Thermal performance U 0,20 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 43 dB (-3; -7)
Ln,w (Cl)
Rating by TGM  
Mass per unit area m 76,4 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 50,0 Magnesite-bound lightweight wood wool board 0,120 2-5 700 1,400
B 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
C 220,0 construction timber (80/..; e=*) 0,120 50 450 1,600 D
D 220,0 sheep wool [0,041; R=16] 0,041 1 16 1,720 E
E vapour barrier sd≥ 2m 1000
F 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
G 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
G 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 39,3 kg
Share of renewable materials of total weight 60,30 %
Global warming potential (GWP-T) -24,531 kgCO2Äqv.
Energy use of Primary Energy 375,9 MJ
Share of renewable Primary Energy 19,9 %
∑ΔOI3 15,1
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 26,471 -51,003 -24,531 74,716 518,003 592,718 301,188 5,150 306,338 0,067 0,028 1.8665203E-6 0,016

Last update 02.08.2023/hfa.eco2soft