Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 30
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²  
Classified by HFA  
Thermal performance U 0,22 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 46 dB (-4; -9)
Ln,w (Cl)
Rating by TGM  
Mass per unit area m 52,3 kg/m2
Calculation based on gypsum plaster board type DF GF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
A 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
B 24,0 planking spruce wood 0,120 50 450 1,600 D
C 220,0 spruce wood floor joists (80/*); e=* 0,120 50 450 1,600 D
D 220,0 sheep wool [0,041; R=16] 0,041 1 16 1,720 E
E vapour barrier sd≥ 6m 1000
F 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
G 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
G 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 32,1 kg
Share of renewable materials of total weight 62,66 %
Global warming potential (GWP-T) -34,342 kgCO2Äqv.
Energy use of Primary Energy 315,6 MJ
Share of renewable Primary Energy 26,8 %
∑ΔOI3 9,4
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 17,457 -51,799 -34,342 84,476 546,931 631,407 231,106 5,150 236,256 0,055 0,024 1.4451756E-6 0,017

Last update 02.08.2023/hfa.eco2soft