Skip to main content
Regional validity

Scope

Holzbetonverbund
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 60,0 cement screed m' approx. 150 kg/m² 1,330 50-100 2500 1,080 A1
B plastic separation layer 0,200 100000 1400 1,400 E
C 30,0 impact sound absorbing subflooring MW-T [s' ≤10 MN/m³] 0,033 1 105 1,030 A2
D - variable building material
E 80,0 2,000 80-130 2400 1,000 A1
F 160,0 cross laminated timber 5-ply (first layer minimum 40 mm) 0,130 50 500 1,600 D

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Ln,w(Cl) [dB] Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
gdhbvnxn01-00 D 60,0 390,0 90 0,40 adequate 38 77 (-1,-6) 64,97 502,1
gdhbvnxn01-01 D 90,0 420,0 90 0,39 adequate 38 77 (-1,-6) 65,99 539,9

Last update 30.09.2024/hfa.plb