Skip to main content
Regional validity

Scope

Holzbetonverbund
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 23,0 0,320 11 1150 1,100 A2
B - variable building material
C 80,0 2,000 80-130 2400 1,000 A1
D 160,0 cross laminated timber 5-ply 0,130 50 500 1,600 D
E 75,0
F 50,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
G 25,0 gypsum plaster board type DF 2x12,5mm or 0,250 10 800 1,050 A2
G 25,0 gypsum fibre board 2x12,5mm 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Ln,w(Cl) [dB] Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
gdhbvtxa01b-00 B 20,0 impact sound absorbing subflooring [s' ≤30 MN/m³] 383,0 90 0,32 adequate 36 (2) 73 (-5,-12) 67,66 322,9

Last update 30.09.2024/hfa.plb