intermediate floor solid wood construction, without lining, wet, with filling
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 60,0 | cement screed | 1,330 | 50-100 | 2000 | 1,080 | A1 |
B | plastic separation layer | 0,200 | 100000 | 1400 | 1,400 | E | |
C | - variable insulation material | ||||||
D | - variable building material | ||||||
E | trickling protection | E | |||||
F | - variable building material |
Thickness of layer | Note | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Ln,w(Cl) [dB] | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] | |||
gdmnxn02-04 |
C D F |
30,0
60,0 140,0 |
impact sound absorbing subflooring MW-T [s'=10 MN/m³] elastic bonded fill (m' aprrox. 90 kg/m²) cross laminated timber, minimum 5-ply, d ≥ 140,0; first layer minimum 30mm |
290,0 | 60 | adequate | 46 (-1) | 73 (-2,-8) | 48,47 | 300,0 |
Last update 02.08.2023/hfa.eco2soft