solid wood construction
Cross-section of standard configuration
solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 60,0 cement screed 1,330 50-100 2000 1,080 A1
B 0,2 plastic separation layer 0,200 100000 1400 1,400 E
C - variable insulation material
D 120,0 elastic bonded fill elastic bonded, m' = 180 kg/m² 0,700 1 1500 1,000 A1
E 0,2 trickling protection E
F 140,0 cross laminated timber 0,130 50 500 1,600 D

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Ln,w(Cl) [dB] Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
gdmnxn03-00 C 40,0 impact sound absorbing subflooring MW-T [s'=10 MN/m³] 360,0 60 adequate 45 (-1) 74 (-2,-8) 53,22 409,0