Skip to main content
Regional validity

Scope

solid wood construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 20,0 0,320 11 1150 1,100 A2
B - variable building material
C 60,0 Kalksplittschüttung in Pappwabe, ungebunden (108kg/m²) 0,700 1 1800 1,000 A1
D trickling protection E
E 150,0 cross laminated timber 5-ply (first layer minimum 40 mm) 0,130 50 500 1,600 D
F 70,0 battens 40/40 on acoustic suspension (a=400) 0,120 50 450 1,600
G 60,0 sheep wool [040; 30] 0,040 1 30 1,720 E
H 25,0 gypsum plaster board type DF 2x12,5mm or 0,250 10 800 1,050 A2
H 25,0 gypsum fibre board 2x12,5mm 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Ln,w(Cl) [dB] Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
gdmtxa05b-00 B 30,0 impact sound absorbing subflooring [100; s'=35 MN/m³] 90 0,26 adequate 46 (4) 73 (-7,-16) 52,84 237,3

Last update 05.08.2024/hfa.plb