Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 50,0 cement screed or anhydrite screed 1,330 50-100 2000 1,080 A1
B plastic separation layer 0,200 100000 1400 1,400 E
C - variable building material
D 40,0 fill 0,700 1 1800 1,000 A1
E trickling protection E
F 19,0 particleboard 0,130 50-100 700 1,700 D
G construction timber (80/..; e=*) 0,120 50 450 1,600 D
H - variable insulation material
I 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
J 27,0 resilient channel placed between cladding with spacing
K 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
K 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Ln,w(Cl) [dB] Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
gdrnxa08b-00 C
G
H
30,0
220,0
100,0
impact sound absorbing subflooring MW-T [s'=10 MN/m³]
construction timber
mineral wool [040; ≥16; <1000°C]
411,0 e=625; 60 0,26 adequate 41 70 (,-4) 43,49 226,0
gdrnxa08b-01 C
G
H
30,0
200,0
100,0
impact sound absorbing subflooring MW-T [s'=10 MN/m³]
construction timber
mineral wool [040; ≥16; <1000°C]
391,0 e=625; 60 0,26 adequate 41 (1) 70 (,-5) 43,42 224,7
gdrnxa08b-02 C
G
H
30,0
240,0
100,0
impact sound absorbing subflooring MW-T [s'=10 MN/m³]
construction timber
mineral wool [040; ≥16; <1000°C]
431,0 e=625; 60 0,26 adequate 40 (1) 71 (,-5) 43,55 227,3
gdrnxa08b-03 C
G
H
30,0
220,0
100,0
impact sound absorbing subflooring MW-T [s'=10 MN/m³]
construction timber
mineral wool [035; 50; <1000°C]
411,0 e=625; 60 0,24 adequate 41 70 (,-4) 54,44 229,3
gdrnxa08b-04 C
G
H
30,0
220,0
100,0
impact sound absorbing subflooring MW-T [s'=10 MN/m³]
construction timber
mineral wool [038; ≥33; ≥1000°C]
411,0 e=625; 60 0,26 adequate 41 70 (,-4) 46,31 227,5
gdrnxa08b-05 C
G
H
30,0
220,0
100,0
impact sound absorbing subflooring MW-T [s'=10 MN/m³]
construction timber
cellulose fibre [040; E]
411,0 e=625; 60 0,26 adequate 41 70 (,-5) 39,84 229,4
gdrnxa08b-06 C
G
H
30,0
220,0
100,0
impact sound absorbing subflooring MW-T [s'=10 MN/m³]
construction timber
sheep wool [0,041; R=16]
411,0 e=625; 60 0,27 adequate 41 70 (-1,-6) 39,26 226,0
gdrnxa08b-07 C
G
H
30,0
220,0
100,0
impact sound absorbing subflooring EPS-T [s'=11 MN/m³]
construction timber
mineral wool [040; ≥16; <1000°C]
411,0 e=625; 60 0,27 adequate 43 (1) 70 (-1,-6) 36,04 224,3
gdrnxa08b-08 C
G
H
30,0
220,0
100,0
impact sound absorbing subflooring MW-T [s'=10 MN/m³]
construction timber
mineral wool [040; ≥16; <1000°C]
411,0 e=400; 60 0,27 adequate 48 (1) 67 (-1,-6) 43,36 233,8
gdrnxa08b-09 C
G
H
30,0
220,0
100,0
Polystyrene EPS-W [s'≥26 MN/m³]
construction timber
mineral wool [040; ≥16; <1000°C]
411,0 e=625; 60 0,27 adequate 50 (1) 65 (-2,-7) 36,49 224,4

Last update 02.08.2023/hfa.eco2soft