Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration

Note

Manufacture according to Kerto Ripa ETA 07/0029 or abZ/aBG Z-9.1-100

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 50,0 cement screed 2,300 50-100 2400 1,080 A1
B 40,0 Isover Akustic EP1 impact sound absorbing subflooring MW-T [032; s'=7 MN/m³] 0,032 1 60 1,030 A1
C 250,0 Kerto LVL Ribbed element (Kerto Q 26 mm + Kerto S 51x224 mm); e = 566 0,130 62-82 480 1,880 D
D - variable insulation material cavity insulation
E 27,0 resilient channel
F 30,0 fermacell® gypsum fibre board 2x15 mm or 0,320 13 1150 1,100 A2
F 30,0 gypsum plaster board type DF 2x15mm 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Ln,w(Cl) [dB] Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
gdrnxa12b-00 D 100,0 mineral wool [0,35; ≥20; <1000^C] 397,0 60 42 65 50,20 190,4

Source: Metsä Wood