Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 50,0 cement screed or anhydrite screed 1,330 50-100 2000 1,080 A1
B plastic separation layer 0,200 100000 1400 1,400 E
C - variable building material
D 19,0 particleboard 0,130 50-100 700 1,700 D
E construction timber (80/..; e=*) 0,120 50 450 1,600 D
F - variable insulation material
G 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
H 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
H 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Ln,w(Cl) [dB] Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
gdrnxn04b-00 C
E
F
30,0
220,0
100,0
impact sound absorbing subflooring MW-T
construction timber
mineral wool [040; ≥16; <1000°C]
368,0 e=625; 60 0,26 adequate 63 58 (-5,-12) 38,48 154,0
gdrnxn04b-01 C
E
F
30,0
200,0
100,0
impact sound absorbing subflooring MW-T
construction timber
mineral wool [040; ≥16; <1000°C]
348,0 e=625; 60 0,27 adequate 64 58 (-6,-13) 38,42 152,7
gdrnxn04b-02 C
E
F
30,0
240,0
100,0
impact sound absorbing subflooring MW-T
construction timber
mineral wool [040; ≥16; <1000°C]
388,0 e=625; 60 0,26 adequate 62 59 (-5,-12) 38,54 155,3
gdrnxn04b-03 C
E
F
30,0
220,0
100,0
impact sound absorbing subflooring MW-T
construction timber
mineral wool [035; 50; <1000°C]
368,0 e=625; 60 0,25 adequate 63 58 (-5,-12) 49,43 157,0
gdrnxn04b-04 C
E
F
30,0
220,0
100,0
impact sound absorbing subflooring MW-T
construction timber
mineral wool [038; ≥33; ≥1000°C]
368,0 e=625; 60 0,26 adequate 63 58 (-5,-12) 41,31 155,5
gdrnxn04b-05 C
E
F
30,0
220,0
100,0
impact sound absorbing subflooring MW-T
construction timber
cellulose fibre [040; E]
368,0 e=625; 60 0,26 adequate 63 58 (-5,-12) 34,83 157,4
gdrnxn04b-06 C
E
F
30,0
220,0
100,0
impact sound absorbing subflooring MW-T
construction timber
sheep wool [0,041; R=16]
368,0 e=625; 60 0,28 adequate 63 58 (-5,-12) 34,26 154,0
gdrnxn04b-07 C
E
F
30,0
220,0
100,0
impact sound absorbing subflooring EPS-T
construction timber
mineral wool [040; ≥16; <1000°C]
368,0 e=625; 60 0,28 adequate 66 58 (-6,-13) 31,04 152,3
gdrnxn04b-08 C
E
F
30,0
220,0
100,0
impact sound absorbing subflooring MW-T
construction timber
mineral wool [040; ≥16; <1000°C]
368,0 e=400; 60 0,28 adequate 66 55 (-6,-13) 38,35 161,8
gdrnxn04b-09 C
E
F
30,0
220,0
100,0
Polystyrene EPS-W [0,041]
construction timber
mineral wool [040; ≥16; <1000°C]
368,0 e=625; 60 0,27 adequate 68 55 (-7,-14) 31,49 152,4

Last update 02.08.2023/hfa.eco2soft