intermediate floor timber frame construction, suspended, dry, without filling
| Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
|---|---|---|---|---|---|---|---|
| λ | μ min – max | ρ | c | ||||
| A | 65,0 | Rigidur flooring element 65 MW | A2 | ||||
| B | 18,0 | OSB | 0,130 | 200 | 600 | 1,700 | D |
| C | 200,0 | construction timber (80/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
| D | 200,0 | ISOVER Ultimate | 0,035 | 1 | 20 | 1,030 | A1 |
| E | 24,0 | spruce wood open formwork (24/100, a=400) | 0,120 | 50 | 450 | 1,600 | D |
| F | Rigips acoustic direct hanger Sylomer (decoupled) | ||||||
| G | 30,0 | Rigips Riduro 2x15mm | 0,250 | 4-10 | 1000 | 1,050 | A2 |
| Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Ln,w(Cl) [dB] | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] | ||
Source: Saint-Gobain Austria GmbH
Last update 02.08.2023/nu.ge