Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 65,0 Rigidur flooring element 65 MW A2
B 18,0 OSB 0,130 200 600 1,700 D
C 200,0 construction timber (80/..; e=625) 0,120 50 450 1,600 D
D 200,0 ISOVER Ultimate 0,035 1 20 1,030 A1
E 24,0 spruce wood open formwork (24/100, a=400) 0,120 50 450 1,600 D
F Rigips acoustic direct hanger with CD 60/27
G 15,0 Rigips Riduro 0,250 4-10 1000 1,050 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Ln,w(Cl) [dB] Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
gdrtxa06a-00 F 60,0 Rigips acoustic direct hanger with CD 60/27 358,0 60 0,16 52 (1) 66 (-6,-15) 53,61 91,6

Source: Saint-Gobain Austria GmbH

Last update 02.08.2023/hfa.eco2soft