Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration

Note

Manufacture according to Kerto Ripa ETA 07/0029 or abZ/aBG Z-9.1-100

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 25,0 fermacell® gypsum fibre board (2x12,5mm; 2-layers) dry screed 0,320 13 1150 1,100 A2
B 20,0 Isover Akustic EP3 impact sound absorbing subflooring MW-T [040; s'=40 MN/m³] 0,040 1 180 1,030 A1
C 30,0 fill lime gravel filling; m'=48 kg/m² 0,700 1 1500 1,000 A1
D 250,0 Kerto LVL Ribbed element (Kerto Q 26 mm + Kerto S 51x224 mm); e=566 0,130 62-82 480 1,880 D
E - variable insulation material cavity insulation
F 27,0 resilient channel
G 18,0 fermacell® gypsum fibre board or 0,320 13 1150 1,100 A2
G 18,0 gypsum plaster board type DF 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Ln,w(Cl) [dB] Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
gdrtxa07a-00 E 100,0 mineral wool [0,35; ≥20; <1000^C] 370,0 30 38 (1) 79 (-8,-16) 49,70 132,1

Source: Metsä Wood

Last update 09.06.2026/hfa.plb