Register of building materials used for this application, cross-section (from top to bottom)
|
Thickness [mm] |
Building material |
Thermal performance |
Reaction to fire |
λ |
μ min – max |
ρ |
c |
A |
25,0 |
dry screed |
0,210 |
8 |
900 |
1,050 |
A1 |
B |
|
- variable building material |
|
|
|
|
|
C |
40,0 |
fill |
0,700 |
1 |
1800 |
1,000 |
A1 |
D |
|
trickling protection |
|
|
|
|
E |
E |
18,0 |
OSB |
0,130 |
200 |
600 |
1,700 |
D |
F |
|
construction timber (80/..; e=*) |
0,120 |
50 |
450 |
1,600 |
D |
G |
|
- variable insulation material |
|
|
|
|
|
H |
24,0 |
spruce wood cladding with spacing of cladding boards(24/100); a=400 |
0,120 |
50 |
450 |
1,600 |
D |
I |
12,5 |
gypsum plaster board type DF or |
0,250 |
10 |
800 |
1,050 |
A2 |
I |
12,5 |
gypsum fibre board |
0,320 |
21 |
1000 |
1,100 |
A2 |
Variations of building components
|
Thickness of layer |
Note |
Fire performance |
Thermal performance |
Acoustic performance |
Eco Sustainability |
Mass |
|
Thickness [mm] |
Building material |
Σ |
REI |
U [W/(m²K)] |
Diffusion |
Ln,w(Cl) |
Rw (C,Ctr) |
ΔOI3 |
m [kg/m²] |
gdrtxn01a-00 |
B F G |
30,0 220,0 100,0 |
impact sound absorbing subflooring MW-T construction timber mineral wool [040; ≥16; <1000°C] |
369,5 |
e=625; |
30 |
0,26 |
adequate |
58 (2) |
63 (-5,-12)
| 30,93 |
134,3 |
gdrtxn01a-01 |
B F G |
30,0 200,0 100,0 |
impact sound absorbing subflooring MW-T construction timber mineral wool [040; ≥16; <1000°C] |
349,5 |
e=625; |
30 |
0,26 |
adequate |
58 (3) |
63 (-6,-13)
| 30,86 |
133,0 |
gdrtxn01a-02 |
B F G |
30,0 240,0 100,0 |
impact sound absorbing subflooring MW-T construction timber mineral wool [040; ≥16; <1000°C] |
389,5 |
e=625; |
30 |
0,26 |
adequate |
57 (3) |
65 (-5,-12)
| 30,99 |
135,6 |
gdrtxn01a-03 |
B F G |
30,0 220,0 100,0 |
impact sound absorbing subflooring MW-T construction timber mineral wool [035; 50; <1000°C] |
369,5 |
e=625; |
30 |
0,24 |
adequate |
58 (2) |
63 (-5,-12)
| 42,07 |
137,3 |
gdrtxn01a-04 |
B F G |
30,0 220,0 100,0 |
impact sound absorbing subflooring MW-T construction timber mineral wool [038; ≥33; ≥1000°C] |
369,5 |
e=625; |
30 |
0,26 |
adequate |
58 (2) |
63 (-3,-12)
| 34,84 |
135,8 |
gdrtxn01a-05 |
B F G |
30,0 220,0 100,0 |
impact sound absorbing subflooring MW-T construction timber cellulose fibre [040; E] |
3,369,5 |
e=625; |
30 |
0,26 |
adequate |
58 (2) |
63 (-5,-12)
| 26,98 |
137,7 |
gdrtxn01a-06 |
B F G |
30,0 220,0 100,0 |
impact sound absorbing subflooring MW-T construction timber sheep wool [0,041; R=16] |
369,5 |
e=625; |
30 |
0,28 |
adequate |
58 (3) |
63 (-6,-13)
| 26,69 |
134,3 |
gdrtxn01a-07 |
B F G |
30,0 220,0 100,0 |
impact sound absorbing subflooring EPS-T construction timber mineral wool [040; ≥16; <1000°C] |
369,5 |
e=625; |
30 |
0,27 |
adequate |
61 (3) |
61 (-5,-12)
| 23,32 |
132,6 |
gdrtxn01a-08 |
B F G |
30,0 220,0 100,0 |
impact sound absorbing subflooring MW-T construction timber mineral wool [040; ≥16; <1000°C] |
369,5 |
e=400; |
30 |
0,27 |
adequate |
62 (4) |
60 (-6,-13)
| 30,79 |
142,1 |
gdrtxn01a-09 |
B F G |
30,0 220,0 100,0 |
Polystyrene EPS-W [0,041] construction timber mineral wool [040; ≥16; <1000°C] |
369,5 |
e=625; |
30 |
0,27 |
adequate |
65 (4) |
59 (-6,-13)
| 23,76 |
132,7 |