Register of building materials used for this application, cross-section
(from top to bottom)
|
Thickness [mm] |
Building material |
Thermal performance |
Reaction to fireklasse EN |
λ |
μ min – max |
ρ |
c |
A |
25,0
|
dry screed
|
0,210
|
8
|
900
|
1,050
|
A1
|
B |
|
- variable building material
|
|
|
|
|
|
C |
40,0
|
fill
|
0,700
|
1
|
1800
|
1,000
|
A1
|
D |
|
trickling protection
|
|
|
|
|
E
|
E |
19,0
|
particleboard
|
0,130
|
50-100
|
700
|
1,700
|
D
|
F |
|
construction timber
(80/..; e=*)
|
0,120
|
50
|
450
|
1,600
|
D
|
G |
|
- variable insulation material
|
|
|
|
|
|
H |
24,0
|
spruce wood
cladding with spacing of cladding boards(24/100); a=400
|
0,120
|
50
|
450
|
1,600
|
D
|
I |
25,0
|
gypsum plaster board type DF
(2x12,5 mm) or
|
0,250
|
10
|
800
|
1,050
|
A2
|
I |
25,0
|
gypsum fibre board
(2x12,5 mm)
|
0,320
|
21
|
1000
|
1,100
|
A2
|
Variations of building components
|
Thickness of layer |
Note |
Fire performance |
Thermal performance |
Acoustic performance |
Eco Sustainability |
Mass |
|
Thickness [mm] |
Building material |
Σ |
REI |
U [W/(m²K)] |
Diffusion |
Ln,w(Cl) [dB] |
Rw (C,Ctr) [dB] |
ΔOI3 |
m [kg/m²] |
gdrtxn02b-00
|
B
F
G
|
30,0
220,0
100,0
|
impact sound absorbing subflooring MW-T
construction timber
mineral wool [040; ≥16; <1000°C]
|
383,0
|
e=625;
|
60
|
0,26
|
adequate
|
58
|
63
(-4,-11)
|
32,34
|
145,9
|
gdrtxn02b-01
|
B
F
G
|
30,0
200,0
100,0
|
impact sound absorbing subflooring MW-T
construction timber
mineral wool [040; ≥16; <1000°C]
|
363,0
|
e=625;
|
60
|
0,26
|
adequate
|
58
(1)
|
63
(-5,-12)
|
32,28
|
144,6
|
gdrtxn02b-02
|
B
F
G
|
30,0
240,0
100,0
|
impact sound absorbing subflooring MW-T
construction timber
mineral wool [040; ≥16; <1000°C]
|
403,0
|
e=625;
|
60
|
0,26
|
adequate
|
57
(1)
|
65
(-4,-11)
|
32,41
|
147,2
|
gdrtxn02b-03
|
B
F
G
|
30,0
220,0
100,0
|
impact sound absorbing subflooring MW-T
construction timber
mineral wool [035; 50; <1000°C]
|
383,0
|
e=625;
|
60
|
0,24
|
adequate
|
58
|
63
(-4,-11)
|
43,29
|
148,9
|
gdrtxn02b-04
|
B
F
G
|
30,0
220,0
100,0
|
impact sound absorbing subflooring MW-T
construction timber
mineral wool [038; ≥33; ≥1000°C]
|
383,0
|
e=625;
|
60
|
0,26
|
adequate
|
58
|
63
(-4,-11)
|
35,17
|
147,4
|
gdrtxn02b-05
|
B
F
G
|
30,0
220,0
100,0
|
impact sound absorbing subflooring MW-T
construction timber
cellulose fibre [040; E]
|
383,0
|
e=625;
|
60
|
0,26
|
adequate
|
58
|
63
(-4,-11)
|
28,70
|
149,3
|
gdrtxn02b-06
|
B
F
G
|
30,0
220,0
100,0
|
impact sound absorbing subflooring MW-T
construction timber
sheep wool [0,041; R=16]
|
383,0
|
e=625;
|
60
|
0,27
|
adequate
|
58
(1)
|
63
(-5,-12)
|
28,12
|
145,9
|
gdrtxn02b-07
|
B
F
G
|
30,0
220,0
100,0
|
impact sound absorbing subflooring EPS-T
construction timber
mineral wool [040; ≥16; <1000°C]
|
383,0
|
e=625;
|
60
|
0,27
|
adequate
|
61
(1)
|
61
(-4,-11)
|
24,90
|
144,2
|
gdrtxn02b-08
|
B
F
G
|
30,0
220,0
100,0
|
impact sound absorbing subflooring MW-T
construction timber
mineral wool [040; ≥16; <1000°C]
|
383,0
|
e=400;
|
60
|
0,27
|
adequate
|
62
(2)
|
60
(-5,-12)
|
32,21
|
153,7
|
gdrtxn02b-09
|
B
F
G
|
30,0
220,0
100,0
|
Polystyrene EPS-W [0,041]
construction timber
mineral wool [040; ≥16; <1000°C]
|
383,0
|
e=625;
|
60
|
0,27
|
adequate
|
65
(2)
|
59
(-5,-12)
|
32,34
|
144,3
|
Last update 02.08.2023/nu.ge