intermediate floor exposed beams, without lining, dry, with filling
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 25,0 | dry screed | 0,210 | 8 | 900 | 1,050 | A1 |
B | - variable insulation material | ||||||
C | 40,0 | fill | 0,700 | 1 | 1800 | 1,000 | A1 |
D | trickling protection | E | |||||
E | 40,0 | planking spruce wood tongue and groove fire resistant planking | 0,120 | 50 | 450 | 1,600 | D |
F | construction timber floor joists (in acc. with structural design) | 0,120 | 50 | 450 | 1,600 | D |
Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Ln,w(Cl) [dB] | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] | ||
gdstxx01-00 | B | 30,0 | impact sound absorbing subflooring MW-T | 30 | 0,66 | adequate | 59 (1) | 57 (-3,-10) | 16,28 | 123,5 |
Last update 02.08.2023/hfa.eco2soft