Building physical assessment

Fire performance REI 60
maximum span = 5 m; maximum load Ed,fi = 5 kN/m²  
Classified by HFA  
Thermal performance U 0,44 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 60 dB (-2; -6)
Ln,w (Cl) 57 dB (-1)
Assessed by TU-GRAZ  
Mass per unit area m 296,7 kg/m2
 
solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 60,0 cement screed 1,330 50-100 2000 1,080 A1
B plastic separation layer 0,200 100000 1400 1,400 E
C 30,0 impact sound absorbing subflooring MW-T [s'= 35MN/m³] 0,035 1 120 1,030 A2
D 60,0 non-bonded chippings 0,700 1 1700 1,000 A1
E trickling protection E
F 140,0 cross laminated timber ≥ 140,0; at least 5-layers, top layer at least 26 mm) 0,130 50 500 1,600 D

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 48,7
calculated with gypsum plaster fire protection board (GKF/DF); this data includes 3-, 5-, and 7-ply cross laminated timber elements;  
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -50,130 0,246 0,098 3,38e-6 0,031 64,226 957,600 1021,826 698,078 31,697 729,775