Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 60
maximum span = 5 m; maximum load Ed,fi = 5 kN/m²  
Classified by HFA  
Fire performance Germany
Classification: REI60  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U
Diffusion adequate
Acoustic performance Rw (C;Ctr) 74 dB (-2; -8)
Ln,w (Cl) 45 dB (-1)
Assessed by Müller-BBM  
Mass per unit area m 409,0 kg/m2
 
solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 60,0 cement screed 1,330 50-100 2000 1,080 A1
B 0,2 plastic separation layer 0,200 100000 1400 1,400 E
C 40,0 impact sound absorbing subflooring MW-T [s'=10 MN/m³] 0,035 1 68 1,030 A1
D 120,0 elastic bonded fill elastic bonded, m' = 180 kg/m² 0,700 1 1500 1,000 A1
E 0,2 trickling protection E
F 140,0 cross laminated timber 0,130 50 500 1,600 D

Ecological rating (per m2 construction area)

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 68,5 kg
Biogenic carbon 98,6 kgCO2 Äqv.
Energy use of Primary Energy 1,049,6 MJ
Share of renewable PE 29,7 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -60,191 0,158 0,027 3,72E-6 0,022 305,272 1.161,515 1.463,987 671,184 52,364 722,765
C1 - C4 116,581 0,033 0,006 1,69E-7 0,003 6,443 -1.160,600 -1.152,789 66,483 0,000 85,203
A1 - C4 57,562 0,194 0,034 3,89E-6 0,024 311,717 0,915 311,780 737,898 52,364 817,967

Last update 03.09.2019/hfa.plb