Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
intermediate floor timber frame construction, suspended, wet, without filling
Fire performance | REI | 60 |
---|---|---|
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²
Classified by HFA
|
||
Thermal performance | U | 0,26 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 66 dB (-1; -6) |
Ln,w (Cl) | 51 dB (0) | |
Rating by TGM
|
||
Mass per unit area | m | 153,9 kg/m2 |
Calculation based on gypsum plaster board type DF GF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 50,0 | anhydrite screed or cement screed | 0,700 | 10 | 2200 | 1,300 | A1 |
B | plastic separation layer | 0,200 | 100000 | 1400 | 1,400 | E | |
C | 30,0 | impact sound absorbing subflooring MW-T | 0,035 | 1 | 68 | 1,030 | A1 |
D | 18,0 | OSB | 0,130 | 200 | 600 | 1,700 | D |
E | 220,0 | construction timber (80/..; e=*) | 0,120 | 50 | 450 | 1,600 | D |
F | 100,0 | mineral wool [038; ≥33; ≥1000°C] | 0,038 | 1 | 33 | 1,030 | A1 |
G | 24,0 | spruce wood cladding with spacing of cladding boards(24/100); a=400 | 0,120 | 50 | 450 | 1,600 | D |
H | 27,0 | resilient channel (placed between open formwork) | |||||
I | 25,0 | gypsum plaster board type DF (2x12,5 mm) or | 0,250 | 10 | 800 | 1,050 | A2 |
I | 25,0 | gypsum fibre board (2x12,5 mm) | 0,320 | 21 | 1000 | 1,100 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 42,636 | -42,619 | 0,017 | 106,475 | 435,899 | 542,374 | 576,626 | 16,832 | 593,458 | 0,176 | 0,077 | 2.7247129E-6 | 0,043 |