Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 30
maximum span = 5 m; maximum load Ed,fi = 2,62 kN/m²  
Classified by HFA  
Thermal performance U 0,25 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 64 dB (-10; -19)
Ln,w (Cl) 57 dB (6)
EPS-F with a dynamic stiffness of s' ≤ 40MN/m³.  
Rating by TGM  
Mass per unit area
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 50,0 anhydrite screed or cement screed 0,700 10 2200 1,300 A1
B plastic separation layer 0,200 100000 1400 1,400 E
C 30,0 Polystyrene EPS-W [0,041] 0,041 20-50 15 1,450 E
D 40,0 fill 0,700 1 1800 1,000 A1
E trickling protection E
F 18,0 OSB 0,130 200 600 1,700 D
G 220,0 construction timber (80/..; e=*) 0,120 50 450 1,600 D
H 100,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
I 12,0 OSB 0,130 200 600 1,700 D
J 27,0 resilient channel
K 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
K 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 30,8 kg
Share of renewable materials of total weight 14,13 %
Global warming potential (GWP-T) -13,354 kgCO2Äqv.
Energy use of Primary Energy 626,6 MJ
Share of renewable Primary Energy 19,0 %
∑ΔOI3 34,9
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 37,383 -50,737 -13,354 118,798 523,630 642,428 507,793 45,527 553,319 0,140 0,065 2.3237621E-6 0,030

Last update 02.08.2023/hfa.eco2soft