Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 30
maximum span = 5 m; maximum load Ed,fi = 2,62 kN/m² (without floor construction and 12mm OSB; with ceiling beam 60/200)
Classified by HFA  
Classified by HFA  
Fire performance Germany
Classification: F30  
Load Ed,fi according to the German certification document
Proof: DIN 4102-4:2016-05, Tabelle 10.12, Zeile 1  
Thermal performance U
Diffusion adequate
Acoustic performance Rw (C;Ctr) 59 dB (-1; -7)
Ln,w (Cl) 60 dB (0)
Rating by Müller-BBM  
Mass per unit area m 159,3 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 50,0 anhydrite screed 0,700 10 2200 1,300 A1
B plastic separation layer 0,200 100000 1400 1,400 E
C 30,0 impact sound absorbing subflooring MW-T 0,035 1 68 1,030 A1
D 18,0 OSB 0,130 200 600 1,700 D
E 240,0 construction timber (80/..; e=625) 0,120 50 450 1,600 D
F 100,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
G 12,0 OSB 0,130 200 600 1,700 D
H 27,0 resilient channel
I 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
I 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 36,2 kg
Share of renewable materials of total weight 23,81 %
Global warming potential (GWP-T) -18,800 kgCO2Äqv.
Energy use of Primary Energy 704,2 MJ
Share of renewable Primary Energy 18,7 %
∑ΔOI3 38,2
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 41,012 -59,812 -18,800 131,664 616,099 747,764 572,535 32,259 604,794 0,159 0,076 2.7444732E-6 0,030

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 37,9 kg
Biogenic carbon 56,8 kgCO2Äqv.
Energy use of Primary Energy 903,3 MJ
Share of renewable Primary Energy 27,6 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -32,440 0,149 0,024 7.98E-7 0,034 247,226 798,791 1047,247 633,617 42,536 676,301
C1 - C4 77,299 0,009 0,002 6.03E-8 0,001 1,543 -792,867 -790,185 15,168 -28,223 2,544
A1 - C4 46,160 0,162 0,027 8.66E-7 0,034 249,150 6,184 258,185 654,187 14,364 692,439

Last update 02.08.2023/hfa.eco2soft