Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 60
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m² (without floor construction and 12mm OSB; with ceiling beam 80/200)
Classified by IBS  
Classified by HFA  
Thermal performance U 0,25 W/(m2K)
Diffusion adequate
Acoustic performance Rw (C;Ctr) 58 dB (-1; -7)
Ln,w (Cl) 60 dB (0)
Assessed by TGM  
Mass per unit area m 171,1 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 50,0 anhydrite screed or cement screed 0,700 10 2200 1,300 A1
B plastic separation layer 0,200 100000 1400 1,400 E
C 30,0 impact sound absorbing subflooring MW-T 0,035 1 68 1,030 A1
D 18,0 OSB 0,130 200 600 1,700 D
E 220,0 construction timber (80/..; e=625) 0,120 50 450 1,600 D
F 100,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
G 12,0 OSB 0,130 200 600 1,700 D
H 27,0 resilient channel
I 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
I 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 42,9
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -10,229 0,174 0,084 3,28e-6 0,012 127,436 524,432 651,868 617,710 25,504 643,215

Last update 07.05.2020/hfa.plb