Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 60
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m² (without floor construction; with ceiling beam 80/200)
Classified by HFA  
Classified by HFA  
Fire performance Germany
Classification: F60  
Load Ed,fi according to the German certification document
Proof: DIN 4102-4:2016-05, Tabelle 10.12, Zeile 4  
Thermal performance U
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 70 dB (-1; -6)
Ln,w (Cl) 41 dB (1)
Rating by Müller-BBM  
Mass per unit area m 227,6 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 50,0 cement screed or anhydrite screed 1,330 50-100 2000 1,080 A1
B plastic separation layer 0,200 100000 1400 1,400 E
C 30,0 impact sound absorbing subflooring MW-T 0,035 1 68 1,030 A1
D 40,0 fill loose 0,700 1 1800 1,000 A1
E trickling protection E
F 22,0 OSB 0,130 200 600 1,700 D
G 220,0 construction timber (80/..; e=625) 0,120 50 450 1,600 D
H 100,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
I spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
J 27,0 resilient channel placed between cladding with spacing
K 25,0 gypsum plaster board type DF (2x...) or 0,250 10 800 1,050 A2
K 25,0 gypsum fibre board (2x...) 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 33,9 kg
Share of renewable materials of total weight 14,61 %
Global warming potential (GWP-T) -12,997 kgCO2Äqv.
Energy use of Primary Energy 714,4 MJ
Share of renewable Primary Energy 17,2 %
∑ΔOI3 39,9
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 42,337 -55,334 -12,997 122,677 566,129 688,806 591,718 30,299 622,017 0,160 0,076 2.9318725E-6 0,029

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 32,4 kg
Biogenic carbon 48,1 kgCO2Äqv.
Energy use of Primary Energy 915,2 MJ
Share of renewable Primary Energy 26,8 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -23,054 0,143 0,024 7.86E-7 0,027 241,188 708,244 950,858 624,826 64,928 689,890
C1 - C4 70,160 0,017 0,004 8.48E-8 0,002 3,203 -697,178 -692,836 34,558 -23,154 27,004
A1 - C4 48,769 0,166 0,029 8.85E-7 0,029 245,150 11,584 259,784 670,015 41,878 735,769

Last update 02.08.2023/hfa.eco2soft