Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 30
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²  
Thermal performance U 0,27 W/(m2K)
Diffusion adequate
energy storage capacity per unit area above: 104,8 kg/m²  
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 70 dB (-2; -7)
Ln,w (Cl) 43 dB (2)
Mass per unit area m 214,3 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 50,0 cement screed or anhydrite screed 1,330 50-100 2000 1,080 A1
B plastic separation layer 0,200 100000 1400 1,400 E
C 30,0 impact sound absorbing subflooring EPS-T [s'=11 MN/m³] 0,044 20-50 1,450 E
D 40,0 fill 0,700 1 1800 1,000 A1
E trickling protection E
F 19,0 particleboard 0,130 50-100 700 1,700 D
G 220,0 construction timber (80/..; e=*) 0,120 50 450 1,600 D
H 100,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
I 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
J 27,0 resilient channel placed between cladding with spacing
K 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
K 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

OI3Kon 3,1

GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
PEI ne
[MJ]
PEI e
[MJ]
EP
[kg PO4 Äqv.]
POCP
[kg C2H4 Äqv.]
-14,4 0,162 608,8 672,8 0,025 0,013

Last update 30.08.2017/hfa.plb