Regional validity

Scope

Building physical assessment

Fire performance REI 60
Classified by HFA  
Thermal performance U 0,24 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 88 dB (-3; -11)
Ln,w (Cl) 29 dB (2)
Rating by HFA  
Mass per unit area m 315,5 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 60,0 cement screed or anhydrite screed 1,330 50-100 2500 1,080
B plastic separation layer 0,200 100000 1400 1,400 E
C 30,0 impact sound absorbing subflooring MW-T [s'=10 MN/m³] 0,033 1 70 1,030 A1
D 60,0 elastic bonded (PUR) chippings, m' approx. 90 kg/m² line split m'=90 kg/m² 0,700 1 1500 1,000 A1
E trickling protection E
F 18,0 OSB 0,130 200 600 1,700 D
G 240,0 construction timber (80/..; e=625) 0,120 50 450 1,600 D
H 100,0 mineral wool [038; ≥30; ≥1000°C] 0,038 1 30 1,030 A1
I trickling protection E
J 60,0 acoustic direct hanger decoupled with Sylomer and CD-profile (a=400)
K 42,5 0,320 21 1000 1,100 A2
K 42,5 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 43,3 kg
Share of renewable materials of total weight 14,27 %
Global warming potential (GWP-T) -14,942 kgCO2Äqv.
Energy use of Primary Energy 965,6 MJ
Share of renewable Primary Energy 17,2 %
∑ΔOI3 54,9
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 54,916 -69,858 -14,942 165,629 714,564 880,193 799,971 53,177 853,148 0,217 0,102 4.0079124E-6 0,042

Last update 02.08.2023/hfa.eco2soft