Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 30
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²  
Classified by IBS  
Thermal performance U 0,26 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 63 dB (-6; -13)
Ln,w (Cl) 58 dB (3)
Assessed by TGM  
Mass per unit area m 133,0 kg/m2
Calculation based on gypsum plaster board type DF GF
 
timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 25,0 dry screed 0,210 8 900 1,050 A1
B 30,0 impact sound absorbing subflooring MW-T 0,035 1 68 1,030 A1
C 40,0 fill 0,700 1 1800 1,000 A1
D trickling protection E
E 18,0 OSB 0,130 200 600 1,700 D
F 200,0 construction timber (80/..; e=*) 0,120 50 450 1,600 D
G 100,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
H 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
I 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
I 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 30,9
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -16,623 0,129 0,056 2,73e-6 0,007 93,349 435,489 528,839 475,969 16,832 492,801

Last update 07.05.2020/hfa.plb