Building physical assessment

Fire performance REI 60
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²  
Classified by HFA  
Thermal performance U 0,26 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 65 dB (-4; -11)
Ln,w (Cl) 57 dB (1)
Rating by TGM  
Mass per unit area m 145,6 kg/m2
Calculation based on gypsum plaster board type DF GF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 25,0 dry screed 0,210 8 900 1,050 A1
B 30,0 impact sound absorbing subflooring MW-T 0,035 1 68 1,030 A1
C 40,0 fill 0,700 1 1800 1,000 A1
D trickling protection E
E 18,0 OSB 0,130 200 600 1,700 D
F 240,0 construction timber (80/..; e=*) 0,120 50 450 1,600 D
G 100,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
H 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400 0,120 50 450 1,600 D
I 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
I 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 29,8 kg
Share of renewable materials of total weight 20,26 %
Global warming potential (GWP-T) -19,689 kgCO2Äqv.
Energy use of Primary Energy 588,0 MJ
Share of renewable Primary Energy 17,7 %
∑ΔOI3 30,5
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 27,460 -47,149 -19,689 103,948 476,517 580,464 484,024 16,832 500,856 0,128 0,056 2.8411338E-6 0,023