intermediate floor exposed beams, without lining, wet, with filling
Fire performance | REI | 30 |
---|---|---|
maximum span = 5 m; maximum load Ed,fi = 5,5 kN/m² (without floor construction; with exposed beams 180/240)
Classified by IBS Classified by HFA
|
||
Thermal performance | U | 0,76 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 62 dB (-1; -7) |
Ln,w (Cl) | 61 dB (-4) | |
Assessed by TGM
|
||
Mass per unit area | m | 199,9 kg/m2 |
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 50,0 | cement screed | 1,330 | 50-100 | 2000 | 1,080 | A1 |
B | plastic separation layer | 0,200 | 100000 | 1400 | 1,400 | E | |
C | 30,0 | impact sound absorbing subflooring EPS-T | 0,040 | 20-50 | 11 | 1,450 | E |
D | 40,0 | fill | 0,700 | 1 | 1800 | 1,000 | A1 |
E | trickling protection | E | |||||
F | 40,0 | planking spruce wood tongue and groove fire resistant planking | 0,120 | 50 | 450 | 1,600 | D |
G | construction timber floor joists (in acc. with structural design) | 0,120 | 50 | 450 | 1,600 | D |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 23,446 | -46,458 | -23,012 | 99,849 | 484,789 | 584,638 | 269,452 | 20,845 | 290,296 | 0,078 | 0,039 | 1.0994037E-6 | 0,023 |