Cross-section of standard configuration
solid wood construction
Standard configuration

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

Cross laminated timber:
Var. 00: thickness ≥ 78mm; 3-ply at least, surface layer at least 25 mm
Var. 01: thickness ≥ 94mm; 3-ply at least, surface layer at least 30 mm

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A - variable building material
B solid glued wood e.g. cross laminated timer 0,130 50 500 1,600 D
C - variable building material

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
iwmxxo01a-00 A
B
C
12,5
90,0
12,5
gypsum plaster board type DF / gypsum fibre board
solid glued wood
gypsum plaster board type DF / gypsum fibre board
115,0 60 38 (-2,-5) 19,56 65,0
iwmxxo01a-01 A
B
C

100,0
without gypsum board lining
solid glued wood
without gypsum board lining
100,0 without gypsum board lining 60 33 (-1,-4) 16,58 50,0