Skip to main content
Regional validity

Scope

solid wood construction
Cross-section of standard configuration
solid wood construction
Standard configuration

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A gypsum plaster board type DF 0,250 10 800 1,050 A2
A gypsum fibre board 0,320 21 1000 1,100 A2
B 78,0 cross laminated timber 3- or 5-ply (e.g. thickness ≥ 78mm; 3-ply at least, surface layer at least 25mm) 0,130 50 500 1,600 D
C 60,0 spruce wood battens (60/60; e=625) 0,120 50 450 1,600 D
D 50,0 mineral wool [040; 13] 0,040 1 13 1,030 A2
E gypsum plaster board type DF or 0,250 10 800 1,050 A2
E gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
iwmxxo02a-00 A
A
E
E
12,5
12,5
12,5
12,5
gypsum plaster board type DF
gypsum fibre board
gypsum plaster board type DF
gypsum fibre board
163,0 A/E=12,5 60 40 20,11
iwmxxo02a-01 A
A
E
E
25,0
25,0
25,0
25,0
gypsum plaster board type DF
gypsum fibre board
gypsum plaster board type DF
gypsum fibre board
188,0 A/E=2*12,5 90 42 24,75
iwmxxo02a-02 A
A
E
E
12,5
12,5
25,0
25,0
gypsum plaster board type DF
gypsum fibre board
gypsum plaster board type DF
gypsum fibre board
175,5 A=12,5; E=2*12,5 60 42 22,43

Last update 02.08.2023/nu.ge