internal wall solid wood construction, with dry lining, Gipsplatte
The fire resistance is only valid when wall is used as partition with only one side exposed to fire.
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | gypsum plaster board type DF | 0,250 | 10 | 800 | 1,050 | A2 | |
A | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 | |
B | 78,0 | cross laminated timber 3- or 5-ply (e.g. thickness ≥ 78mm; 3-ply at least, surface layer at least 25mm) | 0,130 | 50 | 500 | 1,600 | D |
C | 60,0 | spruce wood battens (60/60; e=625) | 0,120 | 50 | 450 | 1,600 | D |
D | 50,0 | mineral wool [040; 13] | 0,040 | 1 | 13 | 1,030 | A2 |
E | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 | |
E | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
Thickness of layer | Note | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] |
Last update 02.08.2023/nu.ge