Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2
A 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
B construction timber (60/100 or 60/160; e=*) 0,120 50 450 1,600 D
C - variable insulation material
D 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2
D 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
iwrxxo01a-00 B
C
100,0
100,0
construction timber
mineral wool [040; ≥16; <1000°C]
125,0 (B=60/100); e=625 30 11,25 25,5
iwrxxo01a-01 B
C
160,0
100,0
construction timber
mineral wool [040; ≥16; <1000°C]
185,0 (B=60/160); e=625 30 11,39 29,2
iwrxxo01a-02 B
C
100,0
100,0
construction timber
mineral wool [035; 50; <1000°C]
125,0 (B=60/100); e=625 30 22,60 28,6
iwrxxo01a-03 B
C
100,0
100,0
construction timber
mineral wool [040; 33; ≥1000°C]
125,0 (B=60/100); e=625 60 38 (-3,-8) 14,18 27,3
iwrxxo01a-04 B
C
100,0
100,0
construction timber
Cellulose fibre [040; 50]
125,0 (B=60/100); e=625 30 38 (-3,-8) 7,79 28,8
iwrxxo01a-05 B
C
100,0
100,0
construction timber
sheep wool [0,041; R=16]
125,0 (B=60/100); e=625 30 6,87 25,5
iwrxxo01a-06 B
C
100,0
100,0
construction timber
mineral wool [040; ≥16; <1000°C]
125,0 (B=60/100); e=400 30 11,00 27,7
iwrxxo01a-07 B
C
160,0
100,0
construction timber
mineral wool [040; ≥16; <1000°C]
185,0 (B=60/160); e=400 30 11,21 33,4
iwrxxo01a-08 B
C
100,0
100,0
construction timber
Wood fibre insulation [039; 45]
125,0 (60/100 od. 60/160; e=625) 30 38 (-3,-8) 8,49 28,4

Last update 02.08.2023/hfa.eco2soft