internal wall timber frame construction, without dry lining, other surface
The fire resistance is only valid when wall is used as partition with only one side exposed to fire.
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 25,0 | gypsum plaster board type DF (2x12,5 mm) or | 0,250 | 10 | 800 | 1,050 | A2 |
A | 25,0 | gypsum fibre board (2x12,5 mm) | 0,320 | 21 | 1000 | 1,100 | A2 |
B | 15,0 | OSB | 0,130 | 200 | 600 | 1,700 | D |
C | construction timber (60/100 or 60/160; e=*) | 0,120 | 50 | 450 | 1,600 | D | |
D | - variable insulation material | ||||||
E | 15,0 | OSB | 0,130 | 200 | 600 | 1,700 | D |
F | 25,0 | gypsum plaster board type DF (2x12,5 mm) or | 0,250 | 10 | 800 | 1,050 | A2 |
F | 25,0 | gypsum fibre board (2x12,5 mm) | 0,320 | 21 | 1000 | 1,100 | A2 |
Thickness of layer | Note | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] |
Last update 02.08.2023/hfa.eco2soft