Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A Rigips Riduro 0,250 4-10 1000 1,050 A2
B construction timber (60/..; e=625) 0,120 50 450 1,600 D
C - variable insulation material
D Rigips Riduro 0,250 4-10 1000 1,050 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
iwrxxo12a-00 A
B
C
D
12,5
120,0
120,0
12,5
Rigips Riduro
construction timber (60/..; e=625)
ISOVER Multi-Kombi Holzrahmenfilz
Rigips Riduro
145,0 60 39 14,33 32,7
iwrxxo12a-01 A
B
C
D
15,0
160,0
160,0
15,0
Rigips Riduro
construction timber (60/..; e=625)
ISOVER Ultimate
Rigips Riduro
190,0 90 43 16,46 40,7
iwrxxo12a-02 A
B
C
D
12,5
120,0
120,0
12,5
Rigips Riduro
construction timber (60/..; e=625)
Hemp insulation [040; 30]
Rigips Riduro
145,0 60 39 9,71 34,9
iwrxxo12a-03 A
B
C
D
12,5
120,0
120,0
12,5
Rigips Riduro
construction timber (60/..; e=625)
Wood fibre insulation [039; 45]
Rigips Riduro
145,0 60 39 9,64 35,9
iwrxxo12a-04 A
B
C
D
12,5
120,0
120,0
12,5
Rigips Riduro
construction timber (60/..; e=625)
Cellulose fibre [040; 50]
Rigips Riduro
145,0 60 39 8,69 36,3

Source: Saint-Gobain Austria GmbH

Last update 02.08.2023/hfa.eco2soft